THE BREEZAIRE PRODUCT LINE
| WK Series |
This is the basic system of choice for standard
applications ranging from under 100 to 2000 cubic feet. This
system is the simplest, user-friendly and the lowest cost
BREEZAIRE series. WK Series systems are compact, self-contained
units. Many other companies have tried to duplicate this
series with minimal success. Our performance speaks for itself.
The WK series has a mechanical thermostat and
its adjustment requires a 1/4" straight
type screwdriver. Adjusting is as easy as turning
the adjusting screw clockwise which lowers the
set point, and counter-clockwise raises it. Units are shipped from the factory fully charged
and ready for use when mounted in a wall and
connected to 115 AC volt source. |

|

|
There are six models to choose from:
| BREEZAIRE Model |
Enclosure Volume |
Electrical |
Dimensions (in) |
Weight |
| WK 1060 |
140 cu.ft. |
3 Amp |
14.25W x 13.25H x 16.38D |
45 lb. |
| WK 2200 |
265 cu.ft. |
4 Amp |
14.25W x 13.25H x 16.38D |
55 lb. |
| WK 3000 |
650 cu.ft. |
5 Amp |
14.25W x 19.75H x 21.63D |
76 lb. |
| WK 4000 |
1000 cu.ft. |
7 Amp |
14.25W x 19.75H x 21.63D |
81 lb. |
| WK 6000 |
1500 cu.ft. |
9.5 Amp |
16.25W x 22.00H x 22.25D |
101 lb. |
| WK 8000 |
2000 cu.ft. |
10 Amp |
16.25W x 22.00H x 22.25D |
101 lb. |
Notes:
- All units are 115 Volt, 60 Hz.
- The 1060 and 2200 models are manufactured with the
cold air out the front (standard) or out the top of unit
(special order).
- All six models can be manufactured with the hot air
out the rear (standard) or out the top of unit (special
order).
- All six models come with the electric cord out the
front (standard) or can be routed out the rear (special
order).
- The 3000 thru 8000 models are shipped from the factory
with the unit configured with the cold air routed out
the front with the option of routing the cold air out
the top by the installer.
For more detailed information go to the WK
Installation Instructions.
|
| WKL Series |
This is the advanced system of choice for
standard applications ranging from under 100 to 2000 cubic
feet. WKL Series systems are compact, self-contained units.
Our performance speaks for itself. This series is equipped
with the BREEZAIRE's affordable Sentry III control system.
This system offers more features that others offer in their
higher-grade models.
The BREEZAIRE's Sentry III control system offers
the following features:
- Large, easy to read, cool green LED display
- Accurate, easy to adjust temperature set points
with continuous display of cabinet temperature.
- Power outage protection.
- Blocked airflow protection, which shuts down
unit and protects wine in case of high temperatures
caused by condenser blockage or fan failure.
- Controls temperature by enclosure (cellar)
air sensors or optional bottle probe.
Units are shipped from the factory fully charged
and ready for use when mounted in a wall and connected
to 115 AC volt source. |

|

|
There are six models to choose from:
| BREEZAIRE Model |
Enclosure Volume |
Electrical |
Dimensions (in) |
Weight |
| WKL 1060 |
140 cu.ft. |
3 Amp |
14.25W x 13.25H x 16.38D |
45 lb. |
| WKL 2200 |
265 cu.ft. |
4 Amp |
14.25W x 13.25H x 16.38D |
55 lb. |
| WKL 3000 |
650 cu.ft. |
5 Amp |
14.25W x 19.75H x 21.63D |
76 lb. |
| WKL 4000 |
1000 cu.ft. |
7 Amp |
14.25W x 19.75H x 21.63D |
81 lb. |
| WK 6000* |
1500 cu.ft. |
9.5 Amp |
16.25W x 22.00H x 22.25D |
101 lb. |
| WK 8000* |
2000 cu.ft. |
10 Amp |
16.25W x 22.00H x 22.25D |
101 lb. |
| * Models will be available in FY2003. |
Notes:
- All units are 115 Volt, 60 Hz.
- The 1060 and 2200 models are manufactured with the
cold air out the front (standard) or out the top of unit
(special order).
- All six models can be manufactured with the hot air
out the rear (standard) or out the top of unit (special
order).
- All six models come with the electric cord out the
front (standard) or can be routed out the rear (special
order).
- The 3000 thru 8000 models are shipped from the factory
with the unit configured with the cold air routed out
the front with the option of routing the cold air out
the top by the installer.
For more detailed information go to the WKL
Installation Instructions.
|
| WKE Series |
Featuring the Exclusive BREEZAIRE Sentinel
II Microprocessor Control System. WKE Series systems with
the SENTINEL II microprocessor-based control system are the
most advanced systems available on the market. No other company
offers the BREEZAIRE Sentinel II performance at any price.
SENTINEL II features a separate
control panel with an LCD display that can be
mounted on the cabinet or in a remote location.
The control panel provides a constant readout
of the temperature, including a separate alarm
indicator light, which allows the user to change
all operating parameters at any time. Built-in
diagnostic routines display trouble codes on
the LCD. Optionally the system can be connected
to a home alarm system.
The system also automatically controls fan
speed to reduce energy use and noise while
providing the optimum cooling under all conditions.
WKE Series systems are compact, self-contained
units.
Units are shipped from the factory fully charged
and ready for use when mounted in a wall and
connected to 115 AC volt source. |

|

|
There are four models to chose from:
| BREEZAIRE Model |
Enclosure Volume |
Electrical |
Dimensions
(in) |
Weight |
| WKE 3000 |
650 cu.ft. |
5 Amps |
14.25W x 19.75H x 21.63D |
76 lb. |
| WKE 4000 |
1000 cu.ft. |
7 Amps |
14.25W x 19.75H x 21.63D |
81 lb. |
| WKE 6000 |
1500 cu.ft. |
9.5 Amps |
16.25W x 22.00H x 22.25D |
101 lb. |
| WKE 8000 |
2000 cu.ft. |
10 Amps |
16.25W x 22.00H x 22.25D |
101 lb. |
Notes:
- All units are 115 Volt, 60 Hz.
- All four models can be manufactured with the hot air
out the rear (standard) or out the top of unit (special
order).
- All four models come with the electric cord out the
front (standard) or can be routed out the rear (special
order).
- All four models are shipped from the factory with the
unit configured with the cold air routed out the front
with the option of routing the cold air out the top by
the installer.
- All four models may be ordered with optional leads
for connection to external alarm system. (special order)
For more detailed information go to the WKE
Installation Instructions.
| WKC Series |
The BREEZAIRE WKC/WKCE Series
cooling units are a compact design with cold
air discharge on the bottom, which makes them
ideal to be installed in cabinets.
Because of their configuration the WKC/WKCE
series cooling units are not rated for specified
number of cubic feet. They are intended for
cabinets and other constricted enclosures.
Ask your BREEZAIRE Dealer for details.
The WKC cooling unit comes with two
(2) optional thermostat systems. Mechanical
(WKC Model) or Digital Electronic (Sentry
III) (WKCE Model).
The WKC Model has a mechanical thermostat
and its adjustments requires a 1/4" straight
type screwdriver. Turning the adjusting
screw clockwise lowers the set point,
counter-clockwise raises it. |

|

|
The WKCE Model has a
digital electronic (Sentry III) thermostat
that adds additional safety and convenience
features: |
- Large, easy to read, green LED
display.
- Accurate, easy to adjust (no
tools needed) readable set points
with continuous reading of enclosure
temperature or displaying of set
point when changing enclosure temperatures.
- Power outage protection, which
delays unit start up after power
outages.
- Blocked airflow protection, which
shuts down unit and protects wine
in case of high temperatures caused
by condenser blockage.
- Controls temperature by enclosure
air sensors or optional bottle
probe.
|

|

|
Units are shipped from the factory fully charged
and ready for use when mounted in a wall and
connected to 115 AC volt source.
There are two sizes and four models to chose
from:
| BREEZAIRE Model |
Electrical |
Dimensions
(in) |
Weight |
| WKC 1060 |
3 Amp |
18W x 10.5H x 16.5D |
45 lb. |
| WKCE 1060 |
3 Amp |
18W x 10.5H x 16.5D |
45 lb. |
| WKC 2200 |
4 Amp |
18W x 10.5H x 16.5D |
55 lb. |
| WKCE 2200 |
4 Amp |
18W x 10.5H x 16.5D |
55 lb. |
Notes:
- All units are 115 Volt, 60 Hz.
- All cabinet Units can be manufactured with
the Hot air out the rear (standard) or out
the top of unit (special order).
- Both cabinet models come with the electric
cord out the front (standard) or can be routed
out the bottom near the rear of the unit
(special order).
For more detailed information go to the WKC/WKCE
Installation Instructions.
| WKS
Series |
When our self-contained
series will not meet your needs then
the WKS split design will provide the
flexibility needed to create an ideal
installation or deal with unusual site
problems. BREEZAIRE WKS Series cooling
systems are special split systems that
allow mounting of the cooling (evaporator)
module in the enclosure to be cooled
and the exhaust (condenser) module
as far as 100 feet away. The systems
are designed - when installed in a
properly constructed enclosure - to
provide a constant selectable temperature
between 48 and 63 degrees Fahrenheit
while maintaining 50 to 75 percent
relative humidity.
WKS Series systems are
designed for easy installation
by any, properly equipped,
qualified air conditioning
or refrigeration service
technician. Two copper tubes
connect the two modules and
power is hard wired to the
units using adequately sized
110 AC volt electrical source.
These systems must be charged
with refrigerant during installation.
The WKS series uses BREEZAIRE's
rugged adjustable mechanical
thermostat. |

|

|
There are two models to choose from:
| BREEZAIRE Model |
Enclosure
Volume |
Electrical |
Dimensions
(in) |
Weight |
| WKS 2200 Fan/Coil |
265 cu.ft. |
1 Amp |
22.00W x 11.00H x 8.00D |
25 lb. |
| WKS 2200 Condenser |
265 cu.ft. |
4 Amps |
14.00W x 10.00H x 12.00D |
35 lb. |
| WKS 4000 Fan/Coil |
1000 cu.ft. |
1.5 Amps |
14.25W x 19.75H x 12.38D |
45 lb. |
| WKS 4000 Condenser |
1000 cu.ft. |
7.5 Amps |
14.25W x 19.75H x 12.38D |
55 lb. |
Notes:
- The WKS 2200 is shipped from
the factory with the unit configured
with the cold air routed out
the front (standard) or out the
top of unit (special order).
- The WKS 4000 is shipped from
the factory with the unit configured
with the cold air routed out the
front with the option of routing
the cold air out the top by the
installer.
For more detailed information go
to the WKS
2200 Installation Instructions or
the WKS
4000 Installation instructions
Copyright © 2002-2005 Breezaire
Products Company. All rights reserved.
BREEZAIRE Logo and Breezaire are registered
trademark of Breezaire Products Company.
Unauthorized reproduction, distribution,
or use without the consent of Breezaire
Products Company may result in severe
civil and criminal penalties, and will
be prosecuted to the maximum extent
possible under California and Federal
Trademark and Copyright laws.
|
|
|
|